Skip to content
Roll over image to zoom in
Click on image to zoom
| Topology |
transformerless |
| Charging voltage (V) |
40-60 V |
| European efficiency (%) |
96.70 |
| Interface 1 |
W-Lan |
| MPP max. voltage range input (V) |
550.00 |
| Min. temperature ambient (°C) |
-25 |
| Protection degree |
IP65 |
| Max. input voltage DC (V) |
600.00 |
| Interface 2 |
RS485 |
| Number of independent MPPT (pcs) |
2 |
| Total number of string inputs |
2 |
| Surge protection AC |
type 3 |
| Max. generator power DC (kWp) |
9.00 |
| Charging current (A) |
120.00 |
| Max. input current DC (A) total |
32.00 |
| Max. output current (A) |
27.30 |
| Max. AC power (kVA) |
6.00 |
| Battery Connection |
DC |
| Min. voltage range input (V) |
58 |
| Start input voltage (V) |
58 |
| Display |
w/o display |
| MPP min. voltage range input (V) |
60.00 |
| Max. efficiency (%) |
97.60 |
| Integrated DC switch |
yes |
| Surge protection DC |
type 2 |
| Backup system light |
yes |
| Max. short circuit current (A) total |
46.00 |
| Max. short circuit current per MPPT (A) |
23.0\/23.0 |
| AC nominal power (kW) |
6.00 |
| Max. input current per MPPT (A). |
16.0\/16.0 |
Roll over image to zoom in
Click on image to zoom