Description
Even an innovative system like the Fronius GEN24 constantly needs new impulses for improvement. The Primo and Symo series are now available with the storage connection still deactivated at the factory. You decide for yourself whether and when you want to use this function by means of an activation code. Of course, you will still receive the familiar version with the battery port already activated - distinguished by the “plus” after the GEN24 in the device name. The smart PV-Point emergency power connection with a maximum output power of 3 kW is active in every version. All other functions and interfaces remain the same.
Product advantages:
- Hybrid inverter, 2 MPPT, 1-phase
- Art. no. 6642447
- Manufacturer No. 4,210,142,002
- Storage connection already activated
- Emergency power via Fronius PV-Point
Product features:
- AC power: 4.0 kW
- Number of MPPT: 2
- DC input current: MPPT 1 - 22,0 A, MPPT 2 - 12,0 A
- Battery connection: active
- AC connection: 1-phase
- Communication: WLAN, 2 x Ethernet
- Interfaces: 6 x DI (FRE), 6 x DO
- Protection class: IP66
- Cooling: active
- Dimensions: 530 x 474 x 165 mm (H x W x D)
- Weight: 15.4 kg
Specification
| Brand | ["Fronius"] |
|---|
| Topology | transformerless |
|---|---|
| Max. generator power DC (kWp) | 6.00 |
| Start input voltage (V) | 80 |
| Max. input current per MPPT (A). | 22\/12 |
| Min. temperature ambient (°C) | -40 |
| Backup system full | yes with supply |
| Backup system light | no |
| Max. input voltage DC (V) | 600.00 |
| Protection degree | IP66 |
| Number of independent MPPT (pcs) | 2 |
| AC nominal power (kW) | 4.00 |
| Arc Fault Circuit Interrupter | no |
| Max. input current DC (A) total | 34.00 |
| Surge protection AC | type 3 |
| Max. AC power (kVA) | 4.00 |
| Decibel | 42 |
| European efficiency (%) | 97.10 |
| MPP max. voltage range input (V) | 600.00 |
| Degree of protection IP | IP66 |
| Interface 1 | RS485 |
| Total number of string inputs | 4 |
| Battery Connection | AC/DC |
| Step-Up converter | yes |
| Display | w/o display |
| Max. short circuit current per MPPT (A) | 36\/19 |
| Max. short circuit current (A) total | 55.00 |
| Max. efficiency (%) | 97.60 |
| Max. output current (A) | 18.20 |
| DC connector type | spring-type terminal |
| Integrated DC switch | yes |
| Surge protection DC | type 2 |
| Contact ripple control receiver | yes |
| Interface 2 | Ethernet |
| Contact for self-consumption optimization (e.g. for heat pump) | 4 |
| Charging voltage (V) | 150-455 |
| MPP min. voltage range input (V) | 65.00 |
| Min. voltage range input (V) | 65 |
| Charging current (A) | 22.00 |