Description
Even an innovative system like the Fronius GEN24 constantly needs new impulses for improvement. The Primo and Symo series are now available with the storage connection still deactivated at the factory. You decide for yourself whether and when you want to use this function by means of an activation code. Of course, you will still receive the familiar version with the battery port already activated - distinguished by the “plus” after the GEN24 in the device name. The smart PV-Point emergency power connection with a maximum output power of 3 kW is active in every version. All other functions and interfaces remain the same.
Product advantages:
- Storage connection already activated
- Emergency power via Fronius PV-Point
- Hybrid inverter, 2 MPPT, 1-phase
- Art. no. 6642448
- Manufacturer No. 4,210,143,002
Product features:
- AC power: 4.6 kW
- Number of MPPT: 2
- DC input current: MPPT 1 - 22,0 A, MPPT 2 - 12,0 A
- Battery connection: active
- AC connection: 1-phase
- Communication: WLAN, 2 x Ethernet
- Interfaces: 6 x DI (FRE), 6 x DO
- Protection class: IP66
- Cooling: active
- Dimensions: 530 x 474 x 165 mm (H x W x D)
- Weight: 15.4 kg
Specification
| Brand | ["Fronius"] |
|---|
| AC nominal power (kW) | 4.60 |
|---|---|
| Topology | transformerless |
| Max. short circuit current per MPPT (A) | 36,0\/19,0 |
| Max. input current per MPPT (A). | 22,0\/12,0 |
| Start input voltage (V) | 80 |
| Min. temperature ambient (°C) | -40 |
| European efficiency (%) | 97.20 |
| Backup system full | yes with supply |
| Backup system light | no |
| Max. input voltage DC (V) | 600.00 |
| Protection degree | IP66 |
| Number of independent MPPT (pcs) | 2 |
| Arc Fault Circuit Interrupter | no |
| Max. input current DC (A) total | 34.00 |
| Decibel | 42 |
| Degree of protection IP | IP66 |
| Interface 1 | RS485 |
| Total number of string inputs | 4 |
| Battery Connection | AC/DC |
| Step-Up converter | yes |
| Max. output current (A) | 20.90 |
| Display | w/o display |
| Max. short circuit current (A) total | 55.00 |
| MPP max. voltage range input (V) | 530.00 |
| Max. efficiency (%) | 97.60 |
| DC connector type | spring-type terminal |
| Integrated DC switch | yes |
| Max. AC power (kVA) | 4.60 |
| Contact ripple control receiver | yes |
| Interface 2 | Ethernet |
| Contact for self-consumption optimization (e.g. for heat pump) | 4 |
| Max. generator power DC (kWp) | 6.90 |
| MPP min. voltage range input (V) | 65.00 |
| Charging voltage (V) | 150V-455V |
| Min. voltage range input (V) | 65 |
| Charging current (A) | 22.00 |