Description
Small system, short strings with different alignments is only possible with optimizers? You thought wrong - because with the new 1-phase Smart Energy hybrid inverter from SMA this is no problem. Despite small power classes of 3.6 to 6.0* kW, the device has 3 MPP trackers and a very low DC input voltage of just 60 V. This allows for unusually short strings in a wide variety of orientations. Together with the new SMA Home Storage a successful combination. Because even the smallest version of the storage system can be used with only one unit on the system. So everything remains in a sensible balance - with room to grow.
Product advantages:
- hybrid inverter, 3 MPPT, 1-phase
- Art. no. 6654467
- Manufacturer No. SBSE5.0-50
- Low DC input voltage enables ultra-short strings
- 3 MPP trackers for maximum flexibility
Product Features:
- AC power: 5.0 kW*
- Number of MPPT: 3
- Input voltage: 60 - 480 V DC
- AC connection: 1-phase
- Communication: WLAN, Ethernet, CAN, RS485
- Protection class: IP65
- Cooling: passive
- Weight: 17.5 kg
- Dimensions: 500 x 586 x 236 mm (W x H x D)
*according to VDE-AR-N 4105 limited to 4.6 kVA
Description
| Brand | ["SMA"] |
|---|
| Topology | transformerless |
|---|---|
| Surge protection DC | no |
| Interface 2 | W-Lan |
| Min. temperature ambient (°C) | -25 |
| Protection degree | IP65 |
| Max. input voltage DC (V) | 600.00 |
| European efficiency (%) | 96.80 |
| Contact for self-consumption optimization (e.g. for heat pump) | 1 |
| Backup system full | no |
| Number of independent MPPT (pcs) | 3 |
| Max. short circuit current per MPPT (A) | 30\/30\/30 |
| Start input voltage (V) | 66 |
| Interface 1 | Ethernet |
| AC nominal power (kW) | 5.00 |
| Battery Connection | AC/DC |
| Surge protection AC | no |
| Charging current (A) | 30.00 |
| Decibel | 35 |
| Display | w/o display |
| Max. input current DC (A) total | 45.00 |
| Battery voltage | High Voltage |
| Degree of protection IP | IP65 |
| Max. input current per MPPT (A). | 15\/15\/15 |
| Min. voltage range input (V) | 60 |
| MPP min. voltage range input (V) | 60.00 |
| Charging voltage (V) | 90-500 |
| Max. efficiency (%) | 97.50 |
| Integrated DC switch | yes |
| Total number of string inputs | 3 |
| MPP max. voltage range input (V) | 480.00 |
| Max. output current (A) | 25.00 |
| Max. AC power (kVA) | 5.00 |
| Arc Fault Circuit Interrupter | yes |
| Max. short circuit current (A) total | 60.00 |
| Shadow management | yes |
| Max. generator power DC (kWp) | 10.00 |